met.jpg (12951 bytes)

Model 237H Portable Airborne Particle Counter

237h.jpg (18057 bytes)

0.10 µm minimum threshold setting at 0.1 cfm
Two to six size channels
Four counting modes
Process gas model

Introducing the world’s smallest particle counter with true 0.10 micron sensitivity! In the past if you wanted six size channels and 0.1µm sensitivity, you had to contend with a large, heavy counter. Now, with a breakthrough in design, Met One gives you battery-operated portability, up to six size channels, and 0.1µm sensitivity—all in one compact instrument!

The Model 237H displays count data on the front-panel as total number of particles (cumulative count) or the particles in each size range (differential count). Four counting modes provide quick answers to measurements questions. The manual mode completes one count cycle then turns the air pump off to prolong battery life. Auto mode repeats the count cycle for the number of cycles programmed to allow unattended monitoring. Concentration mode gives a quick estimate (within seconds) of the particle concentration. Beep mode provides one beep after the count exceeds a selected limit, which is handy for isolating sources of particle contamination such as leaks in filter banks.

The Model G237H can be used to count airborne particles in process gases such as argon and nitrogen.

Specifications

Minimum Theshold Setting 0.10 micron at 50% counting efficiency
Flow Rate 0.1cfm
Size Channels configured at the factory
for one of thefollowing combinations:
 
2 channel 0.1, 0.5
4 channel 0.1, 0.3, 0.5, 1.0
5 channel 0.1, 0.2, 0.3, 0.5, 1.0
6 channel 0.1, 0.2, 0.3, 0.5, 0.7, 1.0
Light Source HeNe laser
Coincidence Loss less than5% at 120,000 particles/ft3
Factory Calibration mono-dispersed polystyrene latex spheres (NIST traceable)
Zero Count not more than one count in 15 minutes
Display 7-digit LED
Output RS-232C/RS485 for computer
Location Labels 250, appear on printout
Data Storage 500 samples, rotating buffer
Sample Time 1 second to 24 hours
Hold Time 1 second to 24 hours
Count Alarms 1 to 9,999,999 counts each channel
Concentration Mode 1 second samples, 1 to 10 samples averaged, display updated every second;
displays count per cubic foot or liter
Power 5 watts, +10 V (approx.) (+6 V with battery pack)
Battery Type Rechargeable Ni-Cd
Operating Time 2 hours
Size 6.7" wide x 4.5" high x 11.7" deep (17 cm x 12 cm x 30 cm)
Weight 9.9 lbs (4.5 kg.)
Environment Operating 55–84°F (12–29°C); 10–85% relative humidity, noncondensing
Storage -40–160°F (-40–71°C); up to 98% relative humidity, noncondensing

Ordering Guide
When ordering, specify:
Model: A237H—standard, G237H—for argon, nitrogen, and helium (includes flowmeter)
Number of Size Channels:   2 to 6
Power Options: 100VAC, 115VAC, 220VAC, or 240VAC

Accessories
Relative Humidity/Temperature Sensor
High Pressure Diffuser
Isokinetic Probe
Printer, External
Carrying Case
Download Software: Particle Vision PortAll